APC SMART-UPS SRT 5000VA RM 230V
Gamintojas: APC
Prekės kodas (MPN): SRT5KRMXLI
Prekės kodas (MPN): SRT5KRMXLI
Galite pratęsti garantiją pasirinkdami papildomą terminą.
Garantija
36 mėn.
36 mėn.
| Sandėlis | Sandėlyje / Atvyksta | Kaina (su PVM) | |
|---|---|---|---|
| S5 | 3 vnt. 1-3 d.d. 3 / - vnt. | 7049,21 € | |
| S1 | - / - | 6921,94 € | |
| S2 | - / - | 6956,55 € |
| Pagrindinės savybės |
|---|
| Ups devices and accessories: | Yes |
| Weight, kg: | 54.55 |
| Noise level, db: | 55 |
| Form factor: | Rack |
| Height, mm: | 130 |
| Width, mm: | 432 |
| Depth, mm: | 719 |
| Connections: | SmartSlot |
| Connections: | USB |
| Certification: | CE, CE Mark |
| Input connection: | Hard Wire 3 wire (1PH+N+G) |
| Surge energy rating, j: | 480 |
| Connections: | Contact Closure |
| Connections: | RJ-45 Serial |
| Runtime: | 4 min (full load) / 12 min (half load) |
| Output power, w: | 4500 |
| Nominal input voltage, v: | 230 (220, 240) |
| Frequency range, hz: | 50/60 +/- 3 |
| Output power capacity (va): | 5000 |
| Nominal output voltage, v: | 230 (220, 240) |
| Input frequency, hz: | 45 - 65 |
| Output interface: | 6 x IEC 320 C13, 4 x IEC 320 C19, 2 x IEC Jumpers |
| Battery recharge time, h: | 3 |
| Maximum power, w: | 4500 |
APC SMART-UPS SRT 5000VA RM 230V APC Smart-UPS RT is a family of high-density, performance UPSs for voice and data networks, medical labs, and light industrial applications. Capable of supporting 10kVA in a 6U rack/tower convertible form, users can support power hungry blade servers or heavily loaded equipment racks. This flexible form factor allows standardization across multiple applications. High power internal chargers allow virtually unlimited additional matching battery packs to comply with aggressive runtime demands of business-critical systems. Customers with harsh power environments looking for extremely tight voltage and frequency regulation, internal bypass, and input power factor correction typical of double conversion online topology will get them in the Smart-UPS RT. Aprašymas LCD graphics display has text and mimic diagrams that display modes of operation, system parameters and alarms. Connect the device to a network using a 10 or 100 BASE-T connection. Green mode bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Battery failure notification provides early-warning fault analysis on batteries enabling timely preventive maintenance. Automatic internal bypass supplies utility power to the connected loads in the event of a UPS power overload or fault. Scalable runtime allows additional run time to be quickly added as needed. Intelligent battery management maximizes battery performance, life, and reliability through intelligent, precision charging. Funkcijos LCD graphics display - text and mimic diagrams that display modes of operation, system parameters and alarms 10/100 BaseT connection - connect the device to a network using a 10 or 100 BaseT connection Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault Scalable runtime - allows additional run time to be quickly added as needed Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault Scalable runtime - allows additional run time to be quickly added as needed Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature Plug-and-Play external batteries - ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS Rack/tower convertible - protects the initial investment in the UPS when migrating from tower to rack-mount environment Flash upgradeable firmware - install maintenance releases of firmware remotely using FTP User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement Disconnected battery notification - warns when a battery is not available to provide backup power Audible alarms - provides notification of changing utility power and UPS power conditions Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances Input power factor correction - minimizes installation costs by enabling the use of smaller generators and cabling Generator compatible - ensures clean, uninterrupted power to protected equipment when generator power is used Cold-start capable - provides temporary battery power when the utility power is out Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment |
| Ups devices and accessories: | Yes |
| Weight, kg: | 54.55 |
| Noise level, db: | 55 |
| Form factor: | Rack |
| Height, mm: | 130 |
| Width, mm: | 432 |
| Depth, mm: | 719 |
| Connections: | SmartSlot |
| Connections: | USB |
| Certification: | CE, CE Mark |
| Input connection: | Hard Wire 3 wire (1PH+N+G) |
| Surge energy rating, j: | 480 |
| Connections: | Contact Closure |
| Connections: | RJ-45 Serial |
| Runtime: | 4 min (full load) / 12 min (half load) |
| Output power, w: | 4500 |
| Nominal input voltage, v: | 230 (220, 240) |
| Frequency range, hz: | 50/60 +/- 3 |
| Output power capacity (va): | 5000 |
| Nominal output voltage, v: | 230 (220, 240) |
| Input frequency, hz: | 45 - 65 |
| Output interface: | 6 x IEC 320 C13, 4 x IEC 320 C19, 2 x IEC Jumpers |
| Battery recharge time, h: | 3 |
| Maximum power, w: | 4500 |
APC SMART-UPS SRT 5000VA RM 230V
APC Smart-UPS RT is a family of high-density, performance UPSs for voice and data networks, medical labs, and light industrial applications. Capable of supporting 10kVA in a 6U rack/tower convertible form, users can support power hungry blade servers or heavily loaded equipment racks. This flexible form factor allows standardization across multiple applications. High power internal chargers allow virtually unlimited additional matching battery packs to comply with aggressive runtime demands of business-critical systems. Customers with harsh power environments looking for extremely tight voltage and frequency regulation, internal bypass, and input power factor correction typical of double conversion online topology will get them in the Smart-UPS RT.
Aprašymas
LCD graphics display has text and mimic diagrams that display modes of operation, system parameters and alarms. Connect the device to a network using a 10 or 100 BASE-T connection. Green mode bypasses unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection. Battery failure notification provides early-warning fault analysis on batteries enabling timely preventive maintenance. Automatic internal bypass supplies utility power to the connected loads in the event of a UPS power overload or fault. Scalable runtime allows additional run time to be quickly added as needed. Intelligent battery management maximizes battery performance, life, and reliability through intelligent, precision charging.
Funkcijos
LCD graphics display - text and mimic diagrams that display modes of operation, system parameters and alarms
10/100 BaseT connection - connect the device to a network using a 10 or 100 BaseT connection
Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance
Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
Scalable runtime - allows additional run time to be quickly added as needed
Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
Automatic internal bypass - supplies utility power to the connected loads in the event of a UPS power overload or fault
Scalable runtime - allows additional run time to be quickly added as needed
Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
Plug-and-Play external batteries - ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS
Rack/tower convertible - protects the initial investment in the UPS when migrating from tower to rack-mount environment
Flash upgradeable firmware - install maintenance releases of firmware remotely using FTP
User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement
Disconnected battery notification - warns when a battery is not available to provide backup power
Audible alarms - provides notification of changing utility power and UPS power conditions
Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery
Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances
Input power factor correction - minimizes installation costs by enabling the use of smaller generators and cabling
Generator compatible - ensures clean, uninterrupted power to protected equipment when generator power is used
Cold-start capable - provides temporary battery power when the utility power is out
Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment