APC SMART-UPS 3000VA LCD RM 2U 230V WITH NETWORK CARD
Gamintojas: APC
Prekės kodas (MPN): SMT3000RMI2UNC
Prekės kodas (MPN): SMT3000RMI2UNC
Galite pratęsti garantiją pasirinkdami papildomą terminą.
Garantija
24 mėn.
24 mėn.
| Sandėlis | Sandėlyje / Atvyksta | Kaina (su PVM) | |
|---|---|---|---|
| S5 | - / - | 3838,34 € | |
| S1 | - / - | 3832,02 € | |
| S2 | - / - | 3813,09 € |
| Pagrindinės savybės |
|---|
| Ups devices and accessories: | Yes |
| Form factor: | Rack |
| Input connection: | IEC-320 C20, Schuko CEE 7 / EU1-16P |
| Height, mm: | 86 |
| Width, mm: | 480 |
| Depth, mm: | 683 |
| Weight, kg: | 44.28 |
| Connections: | SmartSlot |
| Connections: | USB |
| Certification: | C-tick, CE, EN 60950, EN/IEC 62040-1-1, EN/IEC 62040-2, GOST, GS Mark, IRAM, VDE, WEEE |
| Noise level, db: | 55 |
| Surge energy rating, j: | 320 |
| Rack height (units): | 2 |
| Connections: | RJ-45 10/100 Base-T |
| Nominal input voltage, v: | 230 (220, 240) |
| Output power, w: | 2700 |
| Output power capacity (va): | 3000 |
| Frequency range, hz: | 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominal |
| Nominal output voltage, v: | 230 (220, 240) |
| Input frequency, hz: | 50/60 +/- 3 |
| Output interface: | 8 x IEC 320 C13, 1 x IEC 320 C19, 2 x IEC Jumpers |
| Battery recharge time, h: | 3 |
| Maximum power, w: | 2700 |
| Runtime: | 3 min (full load) / 11 min (half load) |
| Input voltage, v: | 160 - 286 (151 - 302) |
APC Smart-UPS 3000VA LCD, 2U rack Aprašymas APC Smart-UPS protects your data by supplying reliable, network-grade power in either traditional Tower or Rack-optimized form factors for space constrained business critical applications. Award winning APC Smart-UPS is the perfect UPS for protecting business critical fileservers (Intel or UNIX based), minicomputers, network switches and hubs, Point of Sale, retail/bank back office and ATMs. Rack Mount versions are the choice for rack optimized servers, server appliances, blade servers, other blade devices and rack-mounted network switches and hubs. Funkcijos Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement Wide input voltage range - designed for harsh electrical environments to save battery life LED indicators - provide easy-to-read status of the unit and utility power conditions Boost and Trim Automatic Voltage Regulation (AVR) - eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress High online efficiency - reduces utility costs, generates less heat Energy meter - provides actual kilowatt hours of usage for energy conscious users Predictive replace battery date - dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning Intuitive LCD interface - provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys Single switched outlet group - single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding Sequenced network shutdown and reboot - customize network shutdown and reboot sequence of connected servers and UPSs Outlet group control - turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations Adjustable voltage sensitivity - provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications Adjustable voltage-transfer points - maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation Audible alarms - provides notification of changing utility power and UPS power conditions Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced Cold-start capable - provides temporary battery power when the utility power is out Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced Network manageable - provides remote power management of the UPS over the network Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment Serial connectivity - provides management of the UPS via a serial port Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced Disconnected battery notification - warns when a battery is not available to provide backup power Network manageable - provides remote power management of the UPS over the network Audible alarms - actively let you know if the unit is on battery, if the battery is low or if there is an overload condition LED status indicators - quickly understand unit and power status with visual indicators Serial connectivity - provides management of the UPS via a serial port Disconnected battery notification - warns when a battery is not available to provide backup power |
| Ups devices and accessories: | Yes |
| Form factor: | Rack |
| Input connection: | IEC-320 C20, Schuko CEE 7 / EU1-16P |
| Height, mm: | 86 |
| Width, mm: | 480 |
| Depth, mm: | 683 |
| Weight, kg: | 44.28 |
| Connections: | SmartSlot |
| Connections: | USB |
| Certification: | C-tick, CE, EN 60950, EN/IEC 62040-1-1, EN/IEC 62040-2, GOST, GS Mark, IRAM, VDE, WEEE |
| Noise level, db: | 55 |
| Surge energy rating, j: | 320 |
| Rack height (units): | 2 |
| Connections: | RJ-45 10/100 Base-T |
| Nominal input voltage, v: | 230 (220, 240) |
| Output power, w: | 2700 |
| Output power capacity (va): | 3000 |
| Frequency range, hz: | 47 - 53 Hz for 50 Hz nominal, 57 - 63 Hz for 60 Hz nominal |
| Nominal output voltage, v: | 230 (220, 240) |
| Input frequency, hz: | 50/60 +/- 3 |
| Output interface: | 8 x IEC 320 C13, 1 x IEC 320 C19, 2 x IEC Jumpers |
| Battery recharge time, h: | 3 |
| Maximum power, w: | 2700 |
| Runtime: | 3 min (full load) / 11 min (half load) |
| Input voltage, v: | 160 - 286 (151 - 302) |
APC Smart-UPS 3000VA LCD, 2U rack
Aprašymas
APC Smart-UPS protects your data by supplying reliable, network-grade power in either traditional Tower or Rack-optimized form factors for space constrained business critical applications. Award winning APC Smart-UPS is the perfect UPS for protecting business critical fileservers (Intel or UNIX based), minicomputers, network switches and hubs, Point of Sale, retail/bank back office and ATMs. Rack Mount versions are the choice for rack optimized servers, server appliances, blade servers, other blade devices and rack-mounted network switches and hubs.
Funkcijos
Predicitive failure notification - provides early-warning fault analysis ensuring proactive component replacement
Wide input voltage range - designed for harsh electrical environments to save battery life
LED indicators - provide easy-to-read status of the unit and utility power conditions
Boost and Trim Automatic Voltage Regulation (AVR) - eliminates voltage fluctuations as a source of AV signal degradation and component power-supply stress
High online efficiency - reduces utility costs, generates less heat
Energy meter - provides actual kilowatt hours of usage for energy conscious users
Predictive replace battery date - dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning
Intuitive LCD interface - provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys
Single switched outlet group - single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding
Sequenced network shutdown and reboot - customize network shutdown and reboot sequence of connected servers and UPSs
Outlet group control - turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations
Adjustable voltage sensitivity - provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications
Adjustable voltage-transfer points - maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation
Audible alarms - provides notification of changing utility power and UPS power conditions
Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
Cold-start capable - provides temporary battery power when the utility power is out
Hot-swappable batteries - ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Network manageable - provides remote power management of the UPS over the network
Battery failure notification - provides early-warning fault analysis on batteries enabling timely preventive maintenance
Safety-agency approved - ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment
Serial connectivity - provides management of the UPS via a serial port
Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
User-replaceable batteries - increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
Frequency and voltage regulation - gives higher application availability by correcting poor frequency and voltage conditions without using the battery
Intelligent battery management - maximizes battery performance, life, and reliability through intelligent, precision charging
Power conditioning - protects connected loads from surges, spikes, lightning, and other power disturbances
Temperature-compensated battery charging - prolongs battery life by regulating the charge voltage according to battery temperature
Automatic restart of loads after UPS shutdown - automatically starts up the connected equipment upon the return of utility power
Automatic self-test - periodic battery self-test ensures early detection of a battery that needs to be replaced
Disconnected battery notification - warns when a battery is not available to provide backup power
Network manageable - provides remote power management of the UPS over the network
Audible alarms - actively let you know if the unit is on battery, if the battery is low or if there is an overload condition
LED status indicators - quickly understand unit and power status with visual indicators
Serial connectivity - provides management of the UPS via a serial port
Disconnected battery notification - warns when a battery is not available to provide backup power